Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 52,
  • Issue 3,
  • pp. 339-342
  • (1998)

Combined Near-Infrared Raman Microprobe and Laser Trapping System: Application to the Analysis of a Single Organic Microdroplet in Water

Not Accessible

Your library or personal account may give you access

Abstract

A combined Raman microprobe and laser trapping system using near-infrared (NIR) laser light was developed for the investigation of single organic microdroplets. The NIR laser light is noninvasive and reduces fluorescence interference in the Raman spectrum for organic molecules. The focused laser beam used for the laser trapping of a microdroplet serves simultaneously as the laser microprobe for Raman measurement. With this system, the focused laser spot is about 1 mu m in diameter, which is small enough for the laser trapping of a single toluene microdroplet in water. The system also makes it possible to visualize a focused laser spot together with a laser-trapped microdroplet by using holographic notch filters. The Raman spectrum for a single laser-trapped toluene microdroplet can be obtained from below 100 cm-1 to above 3000 cm-1 with a charge-coupled device (CCD) detector. Fluorescence interference in the Raman spectrum is completely removed by using NIR laser light. The signal-to-noise ratio (SNR), defined as the ratio of the peak height to the standard deviation of the baseline noise in the spectrum, exceeded 250 for the 1003 cm-1 band of a toluene microdroplet at 1 s, which is sufficient to allow identification of the molecular species of a microdroplet.

PDF Article
More Like This
Application of a near-infrared laser tweezers Raman spectroscopy system for label-free analysis and differentiation of diabetic red blood cells

Jinyong Lin, Lingdong Shao, Sufang Qiu, Xingwu Huang, Mengmeng Liu, Zuci Zheng, Duo Lin, Yongliang Xu, Zhihua Li, Yao Lin, Rong Chen, and Shangyuan Feng
Biomed. Opt. Express 9(3) 984-993 (2018)

Near-infrared Raman spectroscopy of single optically trapped biological cells

Changan Xie, Mumtaz A. Dinno, and Yong-qing Li
Opt. Lett. 27(4) 249-251 (2002)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.