Crystallinity Determination of Polylactide by FT-Raman Spectrometry

Not Accessible

Your library or personal account may give you access

Abstract

The complete Raman spectra of isotropically crystalline and amorphous polylactide (PLA) have been successfully obtained with the use of a Fourier transform instrument equipped with a near-IR laser source. The Raman spectra of PLA were recorded at a resolution of 4 cm -1 from a backscattering sampling geometry. The changes in band intensity and shape of Raman spectra in the crystalline PLA samples facilitated the quantification of the crystallinity, which was primarily determined by the change in enthalpy via differential scanning calorimetry (DSC). A comparison of quantitative analysis of crystallinity by a multivariate technique, partial leastsquares (PLS), and a univariate method at the carbonyl stretching band is described. Quantitative analysis of PLA crystallinity was performed after the data preprocessing with the standard normal variate (SNV) method in the combined spectral regions 3100-2800 cm -1 and 2000-200 cm -1 that were determined by the analysis of the correlation spectrum. The use of the calibration model containing mostly 1% D-PLA samples to separately analyze the samples with 1% and 5% D-PLA is discussed. Superior results obtained from the multivariate over the univariate method make PLS the preferred method of choice in quantification of crystallinity. The standard error of prediction (SEP) for the analysis of 1% D-PLA samples with the use of the calibration model described is 0.85 ( J/g), and the SEP for 5% D-PLA samples is 1.35 ( J/g) with the outliers excluded. The discrepancy in analyzing these two types of PLA samples with the use of the same calibration model is also discussed.

PDF Article
More Like This
Effects of high-repetition-rate femtosecond laser micromachining on the physical and chemical properties of polylactide (PLA)

Wei Jia, Yiming Luo, Jian Yu, Bowen Liu, Minglie Hu, Lu Chai, and Chingyue Wang
Opt. Express 23(21) 26932-26939 (2015)

Simultaneous analysis of Cr and Pb in contaminated pork by laser-induced breakdown spectroscopy

Mingyin Yao, Gangfu Rao, Lin Huang, Muhua Liu, Hui Yang, Jinyin Chen, and Tianbing Chen
Appl. Opt. 56(29) 8148-8153 (2017)

The Determination of the Intensities of Raman Lines*

E. J. Rosenbaum, C. C. Cerato, and J. L. Lauer
J. Opt. Soc. Am. 42(9) 670-672 (1952)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.