Design and Performance of a Planar Array Infrared Spectrograph that Operates in the 3400 to 2000 cm-1 Region

Not Accessible

Your library or personal account may give you access

Abstract

A prototype, no-moving-parts, plane array infrared spectrograph (PA-IR) capable of routine spectral acquisition in the 3400 to 2000 cm<sup>-1</sup> region has been constructed. The instrument includes a continuous source, Czerney-Turner type monochromator system and an infrared camera that incorporates a 320 × 256 pixel InSb focal plane array detector cooled with liquid nitrogen. PA-IR spectra (~3400 to 2550 cm<sup>-1</sup>) of polystyrene (PS) and poly(ethylene naphthalate) (PEN) films have been obtained at a resolution of ~8 cm<sup>-1</sup> with excellent signal-to-noise ratios (SNR). Peak-to-peak noise levels of ~1 × 10<sup>-3</sup> absorbance units are observed for single acquisition spectra with 1.5 ms integration times and 17 ms total acquisition times. Integration times as low as 10 μs are possible (with good SNR); however, data acquisition is limited by the frame rate (60 frames/s) of the software acquisition package currently used. In this work, an apertured image of the source is displayed over ~20 rows of the array and the expected square root improvement in SNR is observed when multiple rows and/or frames are averaged. We have also shown that a square root improvement in SNR continues to occur with further signal averaging, providing noise levels as low as 1.5 × 10<sup>-5</sup> absorbance units. Several additional advantages and options associated with the PA-IR method are discussed, including time-resolved spectroscopy, real-time monitoring, and spectroscopic mapping.

PDF Article
More Like This
Czerny-Turner Far Infrared Spectrometer for the 300–10 cm−1 Region

J. W. Russell and H. L. Strauss
Appl. Opt. 4(9) 1131-1136 (1965)

Spectral Emissivity of Hydrogen Chloride from 1000–3400 cm−1*

V. Robert Stull and Gilbert N. Plass
J. Opt. Soc. Am. 50(12) 1279-1285 (1960)

Sharp Line Absorption in Silica near 3400 cm−1*

Arnold M. Bass and Herbert P. Broida
J. Opt. Soc. Am. 47(2) 163-164 (1957)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved