Direct Determination of Carbon Dioxide in Aqueous Solution Using Mid-Infrared Quantum Cascade Lasers

Not Accessible

Your library or personal account may give you access

Abstract

A method for the direct determination of carbon dioxide in aqueous solutions using a room-temperature mid-infrared (MIR) quantum cascade laser at 2330 cm<sup>–1</sup> is reported. The absorption values of different carbon dioxide concentrations were measured in a 119 μm CaF<sub>2</sub> flow-through cell. An optical system made of parabolic mirrors was used to probe the flow cell and to focus the laser beam on the mercury cadmium telluride (MCT) detector. Aqueous carbon dioxide standards were prepared by feeding different mixtures of gaseous N<sub>2</sub> and CO<sub>2</sub> through wash bottles at controlled temperature. The concentration of the dissolved CO<sub>2</sub> was calculated according to Henry's law, taking into account the temperature and the partial pressure of CO<sub>2</sub>. The carbon dioxide standards were connected via a selection valve to a peristaltic pump for subsequent, automated measurement in the flow-through cell. A calibration curve was obtained in the range of 0.338 to 1.350 g/L CO<sub>2</sub> with a standard deviation of the method<i> s</i><sub>xo</sub> equal to 19.4 mg/L CO<sub>2</sub>. The limit of detection was calculated as three times the baseline noise over time and was determined to be 39 mg/L.

PDF Article
More Like This
Carbon dioxide laser based multiple ATR technique for measuring glucose in aqueous solutions

Yitzhak Mendelson, Been-chyuan Lin, Robert A. Peura, and Allen C. Clermont
Appl. Opt. 27(24) 5077-5081 (1988)

Near-infrared tunable diode laser absorption spectroscopy-based determination of carbon dioxide in human exhaled breath

Cunguang Lou, Congrui Jing, Xin Wang, Yuhao Chen, Jiantao Zhang, Kaixuan Hou, Jianquan Yao, and Xiuling Liu
Biomed. Opt. Express 10(11) 5486-5496 (2019)

ICL-based mid-infrared carbon dioxide sensor system for deep-sea natural gas hydrate exploration

Zhiwei Liu, Chuantao Zheng, Chen Chen, Yafei Li, Hongtao Xie, Qiang Ren, Yiding Wang, and Frank K. Tittel
Opt. Express 27(4) 5598-5609 (2019)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved